Service  
Welcome Qingdao Jiangliu Fire Safety products Co., Ltd.
15194277032
×
<Online Service<

Chemical protective clothing purchase standards, performance, use

browse: author:admin source: time:2019-03-09 07:27 classification:Company news
Chemical protective clothing chemical protective clothing, 1990, the American fire protection association (NFPA) and the American society for experimental materials (ASTM) proposed and developed additional standards, and was OSHA
Chemical protective clothing in 1990, the American fire protection association (NFPA) and the American society for experimental materials (ASTM) proposed and developed additional standards, and was recognized by OSHA.The FPA1991 standard sets performance requirements for chemical - and gas-tight suits. These requirements include chemical - and flame-resistant tests for 21 basic chemicals.Fire-fighting anti-chemical Clothers is one of the protective clothing for firefighters, which can be divided into Fire fighting suit, Fire avoiding suit, Fire insulating suit and heavy protective suit.It is a protective clothing worn by firefighters to protect themselves from hazardous chemicals or corrosive substances when they are fighting and rescuing in fire and accident sites with dangerous chemicals and corrosive substances.In 1990, the American fire protection association (NFPA) and the American society for experimental materials (ASTM) proposed and developed additional standards, which were recognized by OSHA.Fire-fighting anti-chemical Clothers is a kind of protective clothing for firefighters.Fire from fire service directory 1 standard 2 forced the performance requirements such as forced introduces 3 kinds forced the hermetic chemical protective clothing forced the semi-closed chemical protective clothing forced closed protective clothing forced the heavy chemical protective clothing as much attention as much light chemical protective clothing 4 through firewire props forced the effect forced the skills a, chemical protective clothing China standard 1. China national standard firefighters chemical protective clothing GA 770-2008 protective clothing chemical protective clothing and general technical requirements of GB 24539-2009 protective clothing alkali chemical protective clothing GB24540-2009 (2) isolated from the rest of China military standard Type gas-protection clothing general standard GJB 2063-94 Type FFY03 gas-protection clothing standard GJB 1971-94 of vent gas containing carbon suits general standard GJB 1750-93, American standard dangerous chemical accidents with airtight Type protective clothing NFPA1991 hazardous chemical protective clothing NFPA1992 splash chemical, biological, protective clothing NFPA1994 terrorist event scene 3, 1 class European standard airtight Type (external) respirator protective clothing (Type 1)EN943-1 of 1 kind of airtight Type (respirator built-in) protective clothing (Type 1) EN943-2 of 2 class not airtight Type protective clothing (Type 2) three kinds of liquid density EN942-1 Type of protective clothing (Type 3) 4 kinds of spray density EN14605 Type protective clothing (Type 4) EN14605 5 classes prevent solid particles protective clothing (5) Type EN ISO 13982-1 (2) & 6 class mild chemical splash proof protective clothing (6) Type EN13034 performance requirementsThe FPA1991 standard sets performance requirements for chemical - and gas-tight suits. These requirements include chemical - and flame-resistant tests for 21 basic chemicals.Basic OSHA standards require level 4 protection: level A, B, C, and D. Workers at each risk level must be equipped with appropriate levels of protective equipment and protective clothing to fully protect users.Level A-- indicates the highest Level of danger and can cause harm to breath, eyes or skin, which may come from toxic vapors, gases, particles, chemical splashes, immersion or exposure to toxic materials.It requires a fully enclosed chemical protective clothing with SCBA or pipe breathing apparatus and appropriate accessories.Level A chemical protective clothing can also be made to conform to the NFPA1991 standard.Level B indicates that the environment requires the highest Level of respiratory protection, but not high Level of skin protection.It requires SCBA or positive pressure line breathing apparatus with escape gas cylinders, plus a hood, protective clothing (one-piece and long-sleeve jacket);One-piece, one or two anti-splash suits;Or can be used alone in the body of protective clothing).Provide other chemical protective clothing the future European standards: the first category: airtight type protective clothing category 2: than the third class: airtight type protective clothing liquid density type protective clothing class 4: spray type dense protective clothing class 5: dust density type protective clothing class 6: limited spray density type protective clothing is introduced using Tychem TK fabrics made big chemical chemical protective clothing, not only have excellent chemical protection performance and excellent physical properties, and in relative comfort.This product is strictly tested by ASTM and is suitable for industrial, dangerous goods and taboo accident treatment.It is resistant to toxic corrosive gases, liquids and some solid chemicals.Its protective properties have been demonstrated in various industrial applications.Can provide Level B and Level A protection.Protective chemical properties: its wide scope of protection, it can defense more than 260 kinds of high-risk chemicals, (26) a variety of dangerous chemicals through the contact Tychem TK materials for eight hours later, found no obvious infiltration in full compliance with ASTM test standard) excellent physical properties, very durable, laceration resistant features such as high visibility: Tychem TK material for orange, in the dark of the visibility is very good, in the case of taboo is safer.It's easier to see in a smoky environment.Fully sealed chemical protective clothing is the protective clothing that firefighters wear when entering the fire or accident site of chemical dangerous goods or corrosive goods, as well as the site of toxic and harmful gases or accidents, looking for the source of fire or accident point, rescuing the victims and carrying out fire fighting and rescue.Acid penetration resistance (80%H2SO460%HNO330%HCL);No penetration and alkali resistance for 60min (6.1mol/LNaOH);Flame retardant performance: flame burning time is no more than 2s, flame burning time is no more than 10s, damage length is no more than 10cm (no melting, dropping phenomenon) weight <7Kg.Tensile strength: longitude and latitude 450N/5cm.Tear resistance: 32N.Acid and alkali resistance: 10mm liquid column lh does not penetrate.Anti-gasoline performance: no crack and no stickiness after 30s of 120# gasoline soaking.Flame retardant performance: flame retardant time is no more than 2s, flame retardant time is no more than 10s, damage length is no more than 10cm, no droplet anti-chemical target performance electrical insulation performance of soles: 5000v.Puncture resistance of sole: 780N.Waterproof performance of the boots: soak in water for 2h without water seepage.Adhesion strength: 0.78kn/m water leakage resistance;5 3L/min sprinkler heads should be flushed for 15min without leakage.Light chemical protective clothing, also known as semi-closed chemical protective clothing, is made of specially developed fiber, which can protect various chemicals and provide flame retardant enough to maintain or even improve the effectiveness of thermal protective clothing.Suitable for protection of dangerous chemicals and have passed CE standard and corresponding type 4 spillage (osmosis) type antistatic EN1149.1 standard measurement applications: usually steel mills, oil chemical plant, telecommunications, aviation, emergency medical department, name of chemical plant closed protective clothing: fully enclosed heavy protective clothing material: acid and alkali resistant flame retardant compound cloth, chemical protective surface color: color design: the built-in Velcro suits mask: impact resistance, resistance to chemical transparent PVC gloves: special chemical resistant gloves or butyl rubber gloves, boots: they can withstand oil, acid and alkali resistant boots size: S, M, L, XL use scope:Chemical disaster rescue, rocket propellant leak rescue, oil tank, oil depot, chamfer of the cabin, chemical cleaning, chemical pipeline crack repair heavy chemical protective clothing fire chemical protective clothing using the flame retardant treatment of brocade silk cloth, double-sided coated flame retardant chemical protective surface glue, only be made by carbonization, do not produce drip, and can keep good strength adhesive as advocate material, made by the joint - sewing - stick a craft clothing subject and gloves, and flame retardant, chemical defense, voltage resistance, resistance to puncture the boots constitute.Check to make sure the respirator works properly before use.Open the protective clothing completely and fix and adjust the built-in respirator.Wear the bottom first, then the sleeves, then the head.Adjust the mask.Connect the hose of the built-in respirator to the mask connector and open the valve.Close the protective clothing (head and back) completely.Main technical indicators fire chemical protective clothing fire flame retardant chemical protective tape performance chemical protective clothing fabric thickness: 0.45 + / - 0.05 mm.Tensile strength of fire and chemical protective clothing: longitude and latitude 450N/5cm.Tear resistance strength of fire and chemical protective clothing: 32N.Anti-acid and alkali penetration performance of fireproof chemical suit: 10mm liquid column lh does not penetrate.Anti-gasoline performance of fireproof chemical suit: no crack and no stickiness after 30s of 120# gasoline soaking.Flame retardant performance of fire protective clothing: after burning time is no more than 2s, flame retardant time is no more than 10s, damage length is no more than 10cm, no melting droplet target performance fire protective clothing sole electrical insulation performance: 5000v.Puncture resistance of fireproof chemical protective clothing sole: 780N.Waterproof performance of firefighting chemical protective clothing boots: soaked in water for 2h, without water seepage.Adhesion strength: 0.78kn/m water leakage resistance of fire protection chemical suit;5 3L/min sprinkler heads should be flushed for 15min without leakage.1. Heavy chemical protective clothing shall not be in direct contact with the flame and molten matter.2. Please carefully check whether the garment is damaged before use. If it is damaged, it is strictly prohibited to use.3. When using heavy chemical protective clothing, it is necessary to pay attention to the close cooperation between the head cover and the mask, and the buckle of the neck and chest must be fastened to ensure the air tightness of the neck and chest.4. After each use, wash with soapy water or sodium carbonate solution according to dirt, then rinse with water, put in a cool and ventilated place, dry and package.5. When folding, lay the opening of the hood on the ground, fold back the hood, neck buckle and two sleeves, fold the garment vertically and overlap left and right, place the gloves on the middle with the toe of the boots facing outward, roll the soles of the boots into rolls, and put them into the packaging bags of heavy chemical protective clothing horizontally.6. During preservation, the heavy chemical protective clothing shall not be exposed to heat and sunlight, and shall not be exposed to active chemicals and various oils.Light chemical protective clothing due to the uniqueness of the fabric, is the protection, durability and comfort of the most perfect combination;The material itself has a protective, rather than through the laminating, laminating products protective due to scratching easily destroyed;Low chip removal, anti-static;Can protect harmful substances, protect workers;And can protect sensitive products and production process, to avoid from human pollution light chemical protective clothing is for fire, emergency workers, factory or laboratory staff into the solid, liquid acid and alkali chemicals site for emergency, rescue, work when wearing a special personal protective clothing.Light chemical protective clothing is not suitable for use at fire sites, accident sites or workplaces where toxic and harmful gases are present.